Skip to content

Capveon III is here: sell to government in the US, Canada and the UK.Read more

Correct Electrical Deficiencies

246-NETWORK CONTRACTING OFFICE 6 (36C246) (VETERANS AFFAIRS, DEPARTMENT OF), North Carolina. Due 8 Dec 2026.

At a glance

Correct Electrical Deficiencies is a federal contract from 246-NETWORK CONTRACTING OFFICE 6 (36C246) (VETERANS AFFAIRS, DEPARTMENT OF), in North Carolina. Responses are due 8 Dec 2026. It was posted 5 Nov 2026. The solicitation number is 36C24627B0001. It is set aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14). Its NAICS code is 236220. The buyer's notice has the documents and how to respond.

Overview

Buyer
246-NETWORK CONTRACTING OFFICE 6 (36C246) (VETERANS AFFAIRS, DEPARTMENT OF)
Place
North Carolina
Type
Federal contract
Solicitation number
36C24627B0001
Status
Open

Key dates

Posted
5 Nov 2026
Responses due
8 Dec 2026
Time and time zone
Not stated. Check the buyer's notice.

Summary

The buyer's description, as posted.

SOW 565-22-500 Correct Electrical Deficiencies Fayetteville VAMC Intent The project consists of correcting electrical deficiencies as noted from previous VA facility assessments. Improvements include; New electrical entrance building, medium voltage loop replacement, replace electrical distribution equipment, ground conductor corrections, incidental electrical equipment cleanup throughout the Fayetteville VAMC, and minor HVAC and Plumbing improvements. Period of performance 1,174 calendar days. Medium Voltage VA owned medium voltage loop and entrance equipment will be modified or replaced with the following scope: Replace existing medium voltage entrance equipment with new at campus entrance. Provide new building: Slab on grade, brick on CMU wall, Slate roof tile (to match existing facility) Provide new VA owned medium voltage cables in concrete encased duct bank for medium voltage loop. Approximately 300. Demo and remove old VA owned medium voltage entrance metal shack. Replace medium voltage sectionalized switch. Provide new metal-clad switchgear with draw-out vacuum circuit breakers. Replace medium voltage oil filled transformer (1) Panel Replacement and Branch Circuit Improvements Correct deficiencies to electrical panels and branch circuit wiring which are not correctly sized, protected, or are at end of useful life, as identified through various inspections over the years. o All work will be phased. All replacements to existing equipment will require the contractor to filled-out a phasing plan for VA approval. All replacements to existing equipment will require a temporary power solution to minimize electrical outage to existing areas. Such deficiencies include: Replace-in-same-room building entrance and large distribution equipment: Normal (service entrance) Switchboards: approx. 2 Generator switchboards: approx. 2 Automatic transfer switch: approx. 7 Replace-in-place distribution panels and panelboards distribution equipment Distribution Panels: approx. 5 Panelboards: approx. 68 Replace undersized feeders Redundant Gound Provide redundant equipment grounding conductor to a portion of the facility. Approx. 100,000 square feet of existing electrical branch circuit distribution in occupied space. HVAC And Plumbing Reroute (vertically & horizontally) Sewer piping and hot water piping to avoid electrical room. Provide exhaust fan to new Medium Voltage building. Incidental Electrical Equipment Cleanup Provide Identification tag to new and existing equipment throughout the facility: approx. 100 tags Clean debris from existing electrical enclosures throughout the facility: approx. 30 enclosures. Correct panel grounding, terminate cable directly to existing panel s ground bar: approx. 30 panels. ALTERNATE NO.1: BASE BID except delete Bldg 1, Floor 1 and Floor 3 of deficiency item 134 which directs the contractor to provide ground conductors in existing conduit. Which is noted on Sheet B01-E200.

Requirements

Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
NAICS code
236220
Product or service code
6150

Official notice

The buyer's own page for this bid, with its documents and any changes.

Read the buyer's notice

All federal contracts
  1. Intent to Sole Source - Type-C A&E Services for Construction of SFS Facility

    W7NS USPFO ACTIVITY NCANG 145 (DEPT OF DEFENSE), NC

    Due27 Nov 2026

  2. FY27 2ND QTR MEAT FOR FCC BUTNER

    FMC BUTNER (JUSTICE, DEPARTMENT OF), NC

    Due27 Nov 2026

  3. FY27 2ND QTR CERTIFIED KOSHER FOR FCC BUTNER

    FMC BUTNER (JUSTICE, DEPARTMENT OF), NC

    Due27 Nov 2026

  4. FY27 2ND QTR MILK FOR FCC BUTNER

    FMC BUTNER (JUSTICE, DEPARTMENT OF), NC

    Due27 Nov 2026

  5. FY27 2ND QTR CERTIFIED HALAL FOR FCC BUTNER

    FMC BUTNER (JUSTICE, DEPARTMENT OF), NC

    Due27 Nov 2026

  6. FY27 2ND QTR SUBSISTENCE FOR FCC BUTNER

    FMC BUTNER (JUSTICE, DEPARTMENT OF), NC

    Due27 Nov 2026

  7. Notice of Intent to Sole Source - Security System Update

    DEFENSE HEALTH AGENCY (DEPT OF DEFENSE), NC

    Due27 Nov 2026

  8. Repair Signal Processor (Mino) & Receiver/Transmitter for U.S. Coast Guard HC-144 Aircraft

    AVIATION LOGISTICS CENTER (ALC)(00038) (HOMELAND SECURITY, DEPARTMENT OF), NC

    Due27 Nov 2026

Pursue it in Capveon

Read the documents, check the requirements against your team and draft the response in one place.

Start pursuing thisGet similar opportunities by email