Multi-Modal Luminescent Paint Systems for Underwater Surface Diagnostics
At a glance
Multi-Modal Luminescent Paint Systems for Underwater Surface Diagnostics is an SBIR or STTR topic from DOW NAVY. Applications close 6 Jan 2027. It was posted 4 Nov 2026. The funding number is 27.TZ topic DON27TZ02-NV007. It is offered as an SBIR or STTR. The funder's notice has the documents and how to apply.
Overview
- Funder
- DOW NAVY
- Place
- Not stated
- Type
- SBIR or STTR topic
- Funding number
- 27.TZ topic DON27TZ02-NV007
- Status
- Open
Key dates
- Posted
- 4 Nov 2026
- Closes
- 6 Jan 2027
- Time and time zone
- Not stated. Check the buyer's notice.
Summary
The funder's description, as posted.
Quantifying coupled boundary layer interactions along hydrodynamic surfaces require non-intrusive, full-field imaging of surface pressure, temperature, and skin friction (shear stress). While optical diagnostics have revolutionized aerodynamic testing, adapting luminescent paints to hydrodynamic testing in water introduces fundamental physical and application constraints that current state-of-the-art systems cannot overcome: - Pressure-Sensitive Paint (PSP): Conventional PSP relies on oxygen-quenching physics. When submerged, oxygen diffusion into the polymer binder is severely inhibited by the liquid boundary layer and low oxygen solubility, rendering standard PSPs insensitive or plagued by extremely slow response times. Furthermore, severe temperature cross-sensitivity corrupts the pressure signal. - Temperature-Sensitive Paint (TSP): Accurate dynamic temperature measurements are crippled by the standard utilization of Taylor's frozen-flow hypothesis, which inaccurately assumes turbulent structures remain unchanged as they advect. In water, non-equilibrium flow, high thermal mass and rapid localized diffusion cause this hypothesis to break down, failing to capture true high-frequency temperature fluctuations. - Mechano-Luminescent Paint (MLP): MLPs offer a direct optical pathway to map shear stress via mechanical deformation. However, current MLP formulations are in their technological infancy, suffering from poor dynamic range, low luminous efficiency, and signal degradation from material fatigue and hydrostatic pressure cross-talk. In addition to the above challenges, current formulations are difficult to apply uniformly over large areas. Existing techniques fail to maintain a consistent, repeatable coating thickness on complex, curved, or non-flat surfaces. This inconsistency skews calibration and compromises measurement reliability across large-field hydrodynamic models. Innovative material architectures, such as utilizing distinct, multi-color mechano-luminescent particles or multi-core/shell dye structures, may enable simultaneous, uncoupled optical separation of pressure, shear, and temperature in all flow environments, i.e. gas, liquid, and multiphase flows. This STTR topic seeks an integrated material, application, and optical processing suite. The system must decouple cross-sensitivities and deliver simultaneous, high dynamic range, full-field quantitative maps of the wall pressure, shear, and temperature fluctuations. Proposals are taken for Phase I and Phase II. Its technical points of contact take questions directly until 2026-12-02. Written questions are taken on DSIP until 2026-12-23.
Eligibility and award
- Funding type
- SBIR or STTR
Official notice
The funder's own page for this notice, with its documents and any changes.
Related open funding
Closes30 Nov 2026
Closes7 Dec 2026
Closes7 Dec 2026
Closes7 Dec 2026
Closes7 Dec 2026
Closes16 Dec 2026
Closes16 Dec 2026
Closes16 Dec 2026
Track it in Capveon
Read the documents, check the eligibility against your organization and keep the deadline in front of your team.