Lightweight, Energy-Efficient Portable Nitrogen Generator for Expeditionary Operations
At a glance
Lightweight, Energy-Efficient Portable Nitrogen Generator for Expeditionary Operations is an SBIR or STTR topic from DOW NAVY. Applications close 6 Jan 2027. It was posted 4 Nov 2026. The funding number is 27.BZ topic DON27BZ02-NV007. It is offered as an SBIR or STTR. The funder's notice has the documents and how to apply.
Overview
- Funder
- DOW NAVY
- Place
- Not stated
- Type
- SBIR or STTR topic
- Funding number
- 27.BZ topic DON27BZ02-NV007
- Status
- Open
Key dates
- Posted
- 4 Nov 2026
- Closes
- 6 Jan 2027
- Time and time zone
- Not stated. Check the buyer's notice.
Summary
The funder's description, as posted.
The United States Marine Corps (USMC) requires high-pressure nitrogen gas at forward operating locations to perform essential maintenance tasks, including aircraft and ground vehicle tire servicing, recoil mechanism servicing, recharging of gas suspension and accumulator components, and filling gas cylinders. Historically, the military relies on pre-filled, heavy steel gas cylinders resupplied through a vulnerable logistics chain. This process creates a severe logistical burden and hazardous material handling risk. Generating nitrogen at the point of need is essential to sustaining mission readiness in distributed, austere, and expeditionary environments consistent with USMC Force Design 2030 and Expeditionary Advanced Base Operations (EABO) concepts. The final product will be employed by USMC maintainers operating from forward tactical enclosures, specifically integrating with the JLTV Electronic Maintenance Shelter (JEMS). The system will provide point-of-need, high-purity nitrogen to service tactical vehicle and aircraft tires, hydraulic accumulators, recoil mechanisms, and suspension struts in support of distributed expeditionary operations. While the USMC currently utilizes a legacy portable nitrogen generation system, it presents severe technical limitations that hinder expeditionary operations. First, the legacy system weighs 450 pounds, severely limiting mobility and requiring a four-person lift. Second, it requires 240-volt single-phase electrical power drawing 25 Amps. This exceeds the standard 120-volt, 25-Amp electrical limits of forward tactical enclosures, such as the Joint Expeditionary Maintenance Shelter (JEMS). Third, the current system only achieves 99.0% nitrogen purity (falling short of the required 99.5% for sensitive aviation and vehicle struts) and suffers from extremely slow flow rates, taking up to 6 hours to fill a standard 244-cubic-foot cylinder. Commercial industry has introduced 120-volt single-phase configurations that achieve high purity. However, these state-of-the-art commercial units fall short of expeditionary physical requirements: they weigh in excess of 650 pounds, require separate external air compressors to operate, and maximize output at only 3,000 pounds per square inch (PSI). No known existing solution simultaneously achieves man-portable weight limits, 120-volt/25-Amp operation, self-contained air compression, high purity (Develop and demonstrate a man-portable, self-contained nitrogen generator capable of producing high-purity (equal to or less than 99.5%) nitrogen at 1,800 to 3,500 pounds per square inch (PSI), operating strictly within a 120-volt, 25-Amp single-phase electrical limit to support United States Marine Corps (USMC) expeditionary maintenance operations. This SBIR topic seeks innovative small business proposals to design, develop, demonstrate, and deliver a prototype device for a man-portable, energy-efficient, self-contained nitrogen generator that overcomes the stated limitations. Proposed approaches may include advanced membrane separation, pressure swing adsorption (PSA) with novel sorbent materials, hybrid separation architectures, lightweight composite enclosures, advanced electric motor/compressor technologies, intelligent power management, or other innovative approaches that meaningfully advance the state of the art. The prototype device must address extreme environmental challenges, specifically maintaining gas separation efficiency in high heat and high humidity, and must physically fit within tactical maintenance shelters. The prototype device shall target the following performance parameters to bound the scope of effort, while remaining open to innovative approaches that may refine specific parameters: Performance Parameter Phase II Threshold (T = Minimum Acceptable) Phase II Objective (O = Desired) Output Pressure (Selectable/Continuous): No less than 3,500 PSI (T); Greater than 3500 PSI (O) Nitrogen Purity: =/- 99.5% (T); =/- 99.99% (O) Continuous…
Shortened here. The full text is in the buyer's notice.
Eligibility and award
- Funding type
- SBIR or STTR
Official notice
The funder's own page for this notice, with its documents and any changes.
Related open funding
Closes30 Nov 2026
Closes7 Dec 2026
Closes7 Dec 2026
Closes7 Dec 2026
Closes7 Dec 2026
Closes16 Dec 2026
Closes16 Dec 2026
Closes16 Dec 2026
Track it in Capveon
Read the documents, check the eligibility against your organization and keep the deadline in front of your team.