Input-Output Unit (IOU) for Secure Processing and Routing of Hull, Mechanical, & Electrical (HM&E) and Navigation Signals
At a glance
Input-Output Unit (IOU) for Secure Processing and Routing of Hull, Mechanical, & Electrical (HM&E) and Navigation Signals is an SBIR or STTR topic from DOW NAVY. Applications closed 25 Nov 2026. It is closed and no longer taking applications. It was posted 7 Oct 2026. The funding number is 27.BZ topic DON27BZ01-NV004. It is offered as an SBIR or STTR. The funder's notice has the documents and how to apply.
Overview
- Funder
- DOW NAVY
- Place
- Not stated
- Type
- SBIR or STTR topic
- Funding number
- 27.BZ topic DON27BZ01-NV004
- Status
- Closed
Key dates
- Posted
- 7 Oct 2026
- Closes
- 25 Nov 2026
- Time and time zone
- Not stated. Check the buyer's notice.
Summary
The funder's description, as posted.
Develop a dust-protected, water splash-resistant Input-Output Unit (IOU) capable of interfacing with legacy and modern equipment to send, receive, process, and route signals throughout the hull and superstructure of naval vessels. IOUs are used on all Navy DDG 51 class ships to transfer Steering Control, Machinery Control, and Damage Control signals, as well as Interior Communication Alarm and Indication, Synchro and Digital Navigation data. They are also used on USN LHA(R) class ships, in Aegis Ashore facilities, and across a variety of Foreign Military Sales (FMS) cases. IOUs serve as a translation point when sending and receiving non-Ethernet traffic, such as synchro and low-level serial data, to Ethernet user systems. IOUs are installed in a variety of air-conditioned and non-air-conditioned spaces. Their use in engineering spaces that historically have relied on Halon 1301 (safe for sensitive electronics) for fire suppression has been complicated by the Navy's transition away from Halon and toward water mist protection systems. Additionally, existing IOUs rely on the integration of a wide variety of circuit card assemblies (CCA) to process different types of signals, creating hardware challenges for lifetime support and technology refresh. The Navy seeks to reduce lifecycle costs with a simplified design that has fewer hardware dependencies, hardware component updates, and more open and modular system architectures. The IOU is intended to be operated continuously. The IOU shall be designed to permit routine maintenance and troubleshooting. Repair actions should be possible while the IOU is energized without loss of required functionality and operating. Reliability and Survivability are essential and all IOU components must demonstrate Mean Time Between Failures (MTBF) in excess of 10,000 hours. While the IOU as a whole product does not exist commercially, the base technology required is available in industry. The focus of this SBIR topic is to integrate the capabilities into a synergized product. Requirements: The Navy requires a dust-protected, water splash-resistant (IEC 60529 IP54-rated) IOU capable of interfacing with legacy and future equipment to send, receive, process, and route signals throughout the hull and superstructure of naval vessels. The enclosure must protect the power supply, cooling components, and electronics necessary to connect serial (RS-232, RS-422, RS-485, NTDS-E), fiber Ethernet, Cat 5 Ethernet (unicast, multicast), analog synchro (60 and 400 Hertz), and analog voltage (AC and DC) capabilities. External connections are made by triaxial, 42-pin, and 92-pin cables, as well as fiber optic connectors to redundant Gigabit Ethernet (GbE) shipboard networks. Design must accommodate an additional fifty percent capacity for future growth from initial defined design specifications and capability descriptions. It must also provide adequate internal cooling while meeting or exceeding IP54 dust and spray requirements. All hardware components must be compliant with Restriction of Hazardous Substances (RoHS) directive 2011/65/EU. Enclosure: Maximum size and weight (excludes external mounting dimensions): Weight: 188 pounds; Depth: 17 inches; Width: 26 inches; Height: 27 inches. The IOU must be mountable from the rear or the bottom and allow cable attachment/removal and reasonable access to all user interfaces and cable attachment points in any mounted configuration. Power Supply: Internal Alternating Current (AC) power supply will connect to two independent 120V, 60Hz shipboard lighting circuits (2 of 3 phases) for redundancy. Synchro reference power (400Hz and 60Hz) is necessary for some user interfaces (separate from IOU AC power). IOUs should require less than 600 Watts of power when fully loaded. IOU must strictly comply with MIL-STD-1399-300, operating reliably on both Type I and Type II power. The design must tolerate all specified voltage and frequency fluctuations, withstand severe voltage spikes, and…
Shortened here. The full text is in the buyer's notice.
Eligibility and award
- Funding type
- SBIR or STTR
Official notice
The funder's own page for this notice, with its documents and any changes.
Related open funding
Closes30 Nov 2026
Closes7 Dec 2026
Closes7 Dec 2026
Closes7 Dec 2026
Closes7 Dec 2026
Closes16 Dec 2026
Closes16 Dec 2026
Closes16 Dec 2026
Find the next one
This one has closed. Every open grant is listed by kind and by state.