Z2DA--657-27-111JB, Install Continuous Water Monitoring System,
At a glance
Z2DA--657-27-111JB, Install Continuous Water Monitoring System, is a federal contract from 255-NETWORK CONTRACT OFFICE 15 (36C255) (VETERANS AFFAIRS, DEPARTMENT OF), in US. Responses are due 7 Dec 2026. It was posted 23 Nov 2026. The solicitation number is 36C25527R0019. It is set aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14). Its NAICS code is 238220. The buyer's notice has the documents and how to respond.
Overview
- Buyer
- 255-NETWORK CONTRACT OFFICE 15 (36C255) (VETERANS AFFAIRS, DEPARTMENT OF)
- Place
- US
- Type
- Federal contract
- Solicitation number
- 36C25527R0019
- Status
- Open
Key dates
- Posted
- 23 Nov 2026
- Responses due
- 7 Dec 2026
- Time and time zone
- Not stated. Check the buyer's notice.
Summary
The buyer's description, as posted.
Project # 657-27-111JB, Install Continuous Water Monitoring System The Department of Veterans Affairs, Network Contracting Office (NCO) 15, has a requirement for Installing a Continuous Water Monitoring System, project number 657-27-111JB, located at the U.S Department of Veterans Affairs, Str. Louis VAMC Jefferson Barracks 1 Jefferson Barracks Drive St. Louis, MO 63125 The following narrative is intended to provide an overview of the scope of work for the proposed project. Period of Performance 210 calendar days after Notice to Proceed (NTP) Scope of Work Contractor shall completely prepare site for building operations, including demolition and removal of existing structures, and furnish labor and materials and perform work for project 657-27-111JB. Justification: This project is required to be in compliance with VHA Directive 1061 to provide Legionella Prevention measuring devices. Building 3: 1 incoming cold water continuous monitoring with pressure and temperature 1 cold water distal Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Building 51: 1 incoming cold water continuous monitoring with pressure and temperature 2 cold water distal -Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Building 52: 1 incoming cold water continuous monitoring with pressure and temperature 1 cold water distal Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Building 53: 1 incoming cold water continuous monitoring with pressure and temperature 1 cold water distal Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Building 59: 1 incoming cold water continuous monitoring with pressure and temperature 1 cold water distal Furthest point from incoming cold water 1 hot water distal Furthest point from incoming hot water 1 hot water source equipment supply temperature 1 hot water source equipment return temperature Monitoring cold and hot temperature at midpoints at each riser Provide full training of new water monitoring equipment and basic I&C training relating to this project. Contractor work must fully comply with VHA Directive 1061 The estimated project cost range to complete this work is Between $500,000 and $1,000,000. Pursuant to 38 USC 8127(d) and in accordance with Public Law 109-461, the Veterans Benefits, Health Care and Information Technology Act of 2006, this construction project will be solicited as a Total set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). The North American Industry Classification Code (NAICS) for this procurement is 238220 Plumbing, Heating and Air-Conditioning Contractors, with a small business size standard of $19.0 million. Contract Type: Firm Fixed. The duration of the project is estimated to be 210 calendar days from Notice to Proceed. This completion period includes final inspection and cleanup of the premises. Award will be made utilizing Highest technically rated with a fair and reasonable price approach in accordance with Federal Acquisition Regulation Part 15. Proposal submission instructions will be included in the solicitation package. The government plans to award without discussions. The offeror is responsible to monitor and download any amendments from the…
Shortened here. The full text is in the buyer's notice.
Requirements
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- NAICS code
- 238220
- Product or service code
- Z2DA
Official notice
The buyer's own page for this bid, with its documents and any changes.
Related open bids
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Pursue it in Capveon
Read the documents, check the requirements against your team and draft the response in one place.