Skip to content

Capveon III is here: sell to government in the US, Canada and the UK.Read more

W065--medical-grade oxygen cylinders/tanks

241-NETWORK CONTRACT OFFICE 01 (36C241) (VETERANS AFFAIRS, DEPARTMENT OF), US. Due 30 Nov 2026.

At a glance

W065--medical-grade oxygen cylinders/tanks is a federal contract from 241-NETWORK CONTRACT OFFICE 01 (36C241) (VETERANS AFFAIRS, DEPARTMENT OF), in US. Responses are due 30 Nov 2026. It was posted 24 Nov 2026. The solicitation number is 36C24127Q0091. Its NAICS code is 532490. The buyer's notice has the documents and how to respond.

Overview

Buyer
241-NETWORK CONTRACT OFFICE 01 (36C241) (VETERANS AFFAIRS, DEPARTMENT OF)
Place
US
Type
Federal contract
Solicitation number
36C24127Q0091
Status
Open

Key dates

Posted
24 Nov 2026
Responses due
30 Nov 2026
Time and time zone
Not stated. Check the buyer's notice.

Summary

The buyer's description, as posted.

The Department of Veterans Affairs, Networking Contracting Office (NCO 01) located in Brockton, MA intends to enter into a sole source procurement, pursuant to the authority of FAR 6.302-1, with Airgas USA, LLC, for the following requirement: Statement of Work General: The contractor will provide delivery of all requirements for individual compressed gas cylinders/tanks to the locations listed in this document. Period of Performance: base year plus one option year Base year: January 1, 2027 - December 31, 2027 Option year one: January 1, 2028 December 31, 2028 Intended Use: To meet the needs for patients requiring oxygen therapy during transport to different locations of the Boston VA Healthcare System within the facilities. The requirement of the following are estimated amount of each specific size, type of material the cylinder is manufactured of, cylinders with integrated regulators and handles. Integrated valve stem regulator with the aluminum cylinder are utilized throughout Boston Healthcare System. Boston VA Healthcare System requires that all of the hospital transport cylinders be light weight cylinders with integrated regulator with wide handle that is secured to the regulator that extends upward for ease of carrying. The integrated regulator must be able to deliver a flow rate of 0.25, 0.5, 1, 2, 3, 4, 6, 8, 10, 15, 25 liters per minute flow. The regulator also must provide a 50 psi outlet port to connection to equipment if needed. Boston VA Healthcare System requires that of the hospital MR compatible transport cylinders be light weight cylinders with integrated regulator with wide handle that is secured to the regulator that extends upward for ease of carrying. The integrated regulator must be able to deliver a flow rate of 0.25, 0.5, 1, 2, 3, 4, 6, 8, 10, 15, 25 liters per minute flow. The regulator also must provide a 50 psi outlet port to connection to equipment if needed. Boston VA Healthcare System requires that all H cylinders are made of Steel with the Diameter Index Safety System. These cylinders are utilized for Emergency Back Up during an oxygen failure or shut down. Place of Performance: West Roxbury VA Medical Center 1400 VFW Pkwy, West Roxbury, MA 02132 Jamaica Plain VA Medical Center 150 South Huntington Ave, Boston, MA 02130 Brockton VA Medical Center 940 Belmont St Brockton, MA 02301 Day and Hours of Operation: West Roxbury VA Medical Center: M-F 0800-1600 or after regular duty hours by calling the respiratory care department for access. Jamaica Plain VA Medical Center: M-F 0800-1600 Brockton VA Medical Center: M-F 0800-1600 Performance Requirements: The contractor must be able to supply the facilities listed above with the medical grade compressed gases listed in Section 8 weekly. Specifically- deliveries are to be made to West Roxbury campus every Monday and Thursday without fail excluding holidays at which point a needs assessment will be completed and the company will push delivery to the next business day. Deliveries will be made twice per week at the Jamaica Plain campus every Monday and Thursday following the same protocol as West Roxbury. Deliveries will be made twice per week at the Brockton campus following same scheduling and protocol as West Roxbury. The contractor will respond to emergency calls within 2 hours. The contractor shall respond to non-emergency call within 24 hours or the next business day. The contractor shall repair all minor cylinder leaks detected and provide a full report of leak tests and any leaks repaired to the Contracting Officer s Representative (COR). Patient and occupation safety require that all tanks meet all regulatory guidelines and the tanks and regulators allow continuous oxygen flow between regulator settings. Safety features include: Oxygen flow that does not stop if the regulator is placed between two numbers. Integrated valve and regulator that is built into tank and doesn t need to be installed by staff. Single valve tank. No tanks with two valves…

Shortened here. The full text is in the buyer's notice.

Requirements

NAICS code
532490
Product or service code
W065

Official notice

The buyer's own page for this bid, with its documents and any changes.

Read the buyer's notice

All federal contracts
  1. DRAWER,ELECTRICAL E

    SPRMM1 DLA MECHANICSBURG (DEPT OF DEFENSE)

    Due27 Nov 2026

  2. 58--BEACON XMTR ASSY,AI, IN REPAIR/MODIFICATION OF

    NAVSUP WEAPON SYSTEMS SUPPORT (DEPT OF DEFENSE)

    Due27 Nov 2026

  3. 58--BEACON RCVR ASSY,AI, IN REPAIR/MODIFICATION OF

    NAVSUP WEAPON SYSTEMS SUPPORT (DEPT OF DEFENSE)

    Due27 Nov 2026

  4. 62--CONTROL,ELECTRIC LI, IN REPAIR/MODIFICATION OF

    NAVSUP WEAPON SYSTEMS SUPPORT (DEPT OF DEFENSE)

    Due27 Nov 2026

  5. 16--STORES MANAGEMENT C, IN REPAIR/MODIFICATION OF

    NAVSUP WEAPON SYSTEMS SUPPORT (DEPT OF DEFENSE)

    Due27 Nov 2026

  6. 16--STORES MANAGEMENT C, IN REPAIR/MODIFICATION OF

    NAVSUP WEAPON SYSTEMS SUPPORT (DEPT OF DEFENSE)

    Due27 Nov 2026

  7. 59--SSE,AIRCRAFT,MATERI, IN REPAIR/MODIFICATION OF

    NAVSUP WEAPON SYSTEMS SUPPORT (DEPT OF DEFENSE)

    Due27 Nov 2026

  8. Due27 Nov 2026

Pursue it in Capveon

Read the documents, check the requirements against your team and draft the response in one place.

Start pursuing thisGet similar opportunities by email