Skip to content

Capveon III is here: sell to government in the US, Canada and the UK.Read more

TECHNOLOGY LICENSING OPPORTUNITY: Heat Pipe Reactor Fire Mitigation and Suppression System

TRIAD - DOE CONTRACTOR (ENERGY, DEPARTMENT OF), New Mexico. Due 20 Dec 2026.

At a glance

TECHNOLOGY LICENSING OPPORTUNITY: Heat Pipe Reactor Fire Mitigation and Suppression System is a federal contract from TRIAD - DOE CONTRACTOR (ENERGY, DEPARTMENT OF), in New Mexico. Responses are due 20 Dec 2026. It was posted 19 Jun 2026. The solicitation number is S-133663. Its NAICS code is 541715. The buyer's notice has the documents and how to respond.

Overview

Buyer
TRIAD - DOE CONTRACTOR (ENERGY, DEPARTMENT OF)
Place
New Mexico
Type
Federal contract
Solicitation number
S-133663
Status
Open

Key dates

Posted
19 Jun 2026
Responses due
20 Dec 2026
Time and time zone
Not stated. Check the buyer's notice.

Summary

The buyer's description, as posted.

The Heat Pipe Reactor Fire Mitigation and Suppression System from Los Alamos National Laboratory, transforms the heat pipes inside an alkali metal-cooled nuclear reactor from passive thermal conduits into active, sensor-driven fire defense components, giving designers of advanced small and microreactors a layered, automated safeguard against one of the most challenging hazards in their systems. By combining an inert gas buffer, a phase change material jacket, automated suppressant injection at multiple points and optional neutron-absorber dispersion into the reactor core, the system delivers redundant protection that responds within milliseconds of detecting fire-like conditions. This system enables advanced reactor developers to meet stringent safety expectations for remote, unattended and space-constrained deployments without redesigning the core architecture around bulky external suppression equipment. How it Works During normal operation, each heat pipe carries thermal energy away from the reactor core through the evaporation and condensation of an alkali metal working fluid, while valves connecting the heat pipe to external suppressant chambers remain closed. Temperature and pressure sensors continuously monitor the heat pipe reactor core and the valves near each heat pipe end, feeding data to a controller that compares readings against predefined thresholds. When a reading crosses the first threshold, the controller opens a valve and forces a fire suppressant material, typically a boron compound, into the interior of the heat pipe. If conditions worsen and a second threshold is crossed, additional valves activate to inject suppressant from the opposite end of the heat pipe, evacuate the working fluid through a dedicated valve and release suppressant into an inert gas chamber that annularly surrounds the heat pipe at the heat exchanger interface. Technical Description The system architecture centers on a heat pipe reactor core engaging a plurality of dual-ended or single-ended heat pipes, where both ends of each heat pipe extend externally of the core block so that suppressant can be introduced from either side of the core. A heat exchanger device sits at the heat rejection end of each heat pipe and defines an enclosed inert gas chamber that annularly surrounds the heat pipe, creating a physical gap between the alkali metal working fluid and any water-based cooling fluid. The chamber adds a second point of failure that must occur before incompatible fluids can interact, and the inert gas itself can serve as a blanketing agent for active flames. A layer of phase change material, typically a salt that doubles as a Class D fire extinguishing agent and alkali metal fire retardant, is disposed on the outer surface of the gas chamber, partitioned by fin-bearing components that both store thermal energy and improve heat transfer to the surrounding cooling fluid. The active suppression and shutdown logic is governed by a controller comprising memory, processor, input/output circuitry and communications circuitry, optionally implemented as a distributed or cloud-based system. First and second valves regulate suppressant flow into each end of the heat pipe interior cavity from dedicated suppressant chambers, while third and fourth valves regulate suppressant flow into the inert gas chamber from separate chambers. The second valve at the heat pipe's far end can also be configured to evacuate working fluid either simultaneously with or prior to suppressant injection, encouraging dispersion of the suppressant throughout the pipe. As an additional shutdown pathway, the reactor core block can include gaps between fuel rods and heat pipes in which a neutron absorber material such as cadmium or a boron compound is preloaded; on detection of an alkali metal fire, the controller can release that absorber into the gaps to reduce core reactivity and aid shutdown, providing a coupled fire-and-reactivity response unique to this design…

Shortened here. The full text is in the buyer's notice.

Requirements

NAICS code
541715
Product or service code
AC32

Official notice

The buyer's own page for this bid, with its documents and any changes.

Read the buyer's notice

All federal contracts
  1. Two (2) Program Assistants - Health Information Management (HIM) Dept. - Santa Fe Service Unit

    ALBUQUERQUE AREA INDIAN HEALTH SVC (HEALTH AND HUMAN SERVICES, DEPARTMENT OF), NM

    Due27 Nov 2026

  2. Two (2) Supply Technicians - Santa Fe Service Unit

    ALBUQUERQUE AREA INDIAN HEALTH SVC (HEALTH AND HUMAN SERVICES, DEPARTMENT OF), NM

    Due27 Nov 2026

  3. Solicitation is Restricted to the Land Management Integrated Resources (LMIR) BPA

    USDA-FS, STEWARDSHIP CONTRACTING BRANCH (AGRICULTURE, DEPARTMENT OF), NM

    Due30 Nov 2026

  4. Y--IE181 - WHS Greenhouse Construction

    INDIAN EDUCATION ACQUISITION OFFICE (INTERIOR, DEPARTMENT OF THE), NM

    Due30 Nov 2026

  5. 6810--501 - Dry Ice Base +4

    262-NETWORK CONTRACT OFFICE 22 (36C262) (VETERANS AFFAIRS, DEPARTMENT OF), NM

    Due30 Nov 2026

  6. Notice to Intent to Sole Source - Pitney Bowes Reserve Account

    NAVAJO AREA INDIAN HEALTH SVC (HEALTH AND HUMAN SERVICES, DEPARTMENT OF), NM

    Due30 Nov 2026

  7. 6810--501 - Dry Ice Base +4

    262-NETWORK CONTRACT OFFICE 22 (36C262) (VETERANS AFFAIRS, DEPARTMENT OF), NM

    Due30 Nov 2026

  8. Request for Information: Multi-Source PNT UE

    FA9453 AFRL RVK (DEPT OF DEFENSE), NM

    Due30 Nov 2026

Pursue it in Capveon

Read the documents, check the requirements against your team and draft the response in one place.

Start pursuing thisGet similar opportunities by email