Skip to content

Capveon III is here: sell to government in the US, Canada and the UK.Read more

Modified Shipping Containers for Guam

ClosedMRPBS MINNEAPOLIS MN (AGRICULTURE, DEPARTMENT OF), Guam. Was due 17 Sep 2026.

At a glance

Modified Shipping Containers for Guam is a federal contract from MRPBS MINNEAPOLIS MN (AGRICULTURE, DEPARTMENT OF), in Guam. Responses were due 17 Sep 2026. It is closed and no longer taking bids. It was posted 15 Sep 2026. The solicitation number is 12639526Q0285. It is set aside: Total Small Business Set-Aside (FAR 19.5). Its NAICS code is 332311. The buyer's notice has the documents and how to respond.

Overview

Buyer
MRPBS MINNEAPOLIS MN (AGRICULTURE, DEPARTMENT OF)
Place
Guam
Type
Federal contract
Solicitation number
12639526Q0285
Status
Closed

Key dates

Posted
15 Sep 2026
Responses due
17 Sep 2026
Time and time zone
Not stated. Check the buyer's notice.

Summary

The buyer's description, as posted.

September 15, 2026 - Modified solicitation to add Questions/Answers with Photos of site location. This is a presolicitation notice issued in accordance with FAR Overhaul subpart 5.101, Presolicitation. (1) Point of contact: Jeanine Goral, Contracting Officer USDA Animal and Plant Health Inspection Service (APHIS) Email: Jeanine.J.Goral@usda.gov Telephonic inquiries will not be honored. (2) Set-asides: Total small business set-aside (3) Codes for services or supplies: PSC: 8145 - Specialized shipping and storage containers NAICS: 332311 - Prefabricated metal and component mfg. (4) Description: Quantity of One (1) Modified 40ft x 8ft shipping container Name Brand (Conex) or Equal to be delivered to the USDA, APHIS, Wildlife Services Guam Program and installed on a concrete pad with electrical hookup at the WS state office on Guam. Specifications required: 40ft HC Steel New-Container (Modified) New 40ft shipping container Preparation of delivery site/pad for Conex Concrete pad is in place, but may need refurbishing Typhoon-rated tie-down strapping/anchoring with installation All exterior surfaces painted and finished with exterior paint formulated to reduce corrosion Silicone roof coating Three (3) 3' x 3' windows with accordion-style typhoon shutters Two windows in room one, one window in room two Two (2) aluminum exterior doors Installed to open outward One entry to room one, one entry to room two Interior sectioning and finishing of container Interior divided into two rooms, separated by a finished and insulated wall w/ interior door Interior door opens so door swings into room one Rooms should be nearly equal in size, with room one slightly larger to accommodate swing of interior door (roughly 55% room one, 45% room two) All interior walls insulated and finished with drywall Spray foam, fiberglass, or rigid board insulation (R-13 or greater) Vinyl or laminate flooring Ceiling insulated and finished with drop ceiling tiles, or drywall Interior height, floor to ceiling, should be 96 inches (± 1 in) Spray foam or rigid board insulation (R-13 or greater) Interior painted and finished Electrical requirements Container electrical hooked up to WS Guam state office electrical system via hookup located on concrete pad at site. Exterior junction box 220v hookup for A/C's, & Appliances 120v electrical hookup to interior 100-amp panel box in room two Two (2) A/C split units, one in each room 12,000 BTU minimum A/C disconnect for each unit Twelve (12) electrical outlets Six (6) outlets per room Four (4) overhead dome or strip lighting fixtures (LED or fluorescent) 40ft HC Steel New-Container (Modified) - New 40ft shipping container - Preparation of delivery site/pad for Conex (Figure 2) o Concrete pad is in place, but may need refurbishing - Typhoon-rated tie-down strapping/anchoring with installation - All exterior surfaces painted and finished with exterior paint formulated to reduce corrosion - Silicone roof coating - Three (3) 3' x 3' windows with accordion-style typhoon shutters o Two windows in room one, one window in room two - Two (2) aluminum exterior doors o Installed to open outward o One entry to room one, one entry to room two Interior sectioning and finishing of container - Interior divided into two rooms, separated by a finished and insulated wall w/ interior door o Interior door opens so door swings into room one o Rooms should be nearly equal in size, with room one slightly larger to accommodate swing of interior door (roughly 55% room one, 45% room two) - All interior walls insulated and finished with drywall o Spray foam, fiberglass, or rigid board insulation (R-13 or greater) - Vinyl or laminate flooring - Ceiling insulated and finished with drop ceiling tiles, or drywall o Interior height, floor to ceiling, should be 96 inches (± 1 in) o Spray foam or rigid board insulation (R-13 or greater) - Interior painted and finished Electrical requirements - Container electrical hooked up to WS Guam state office…

Shortened here. The full text is in the buyer's notice.

Requirements

Set-aside
Total Small Business Set-Aside (FAR 19.5)
NAICS code
332311
Product or service code
8145

Official notice

The buyer's own page for this bid, with its documents and any changes.

Read the buyer's notice

All federal contracts
  1. Due30 Nov 2026

  2. Due2 Dec 2026

  3. Due3 Dec 2026

  4. ABANDONED VEHICLE REMOVAL IDIQ

    NAVSUP FLT LOG CTR YOKOSUKA (DEPT OF DEFENSE), GU

    Due4 Dec 2026

  5. Modular Bulk Storage Crate System for Andersen AFB, Guam

    FA5215 766 ESS PKP (DEPT OF DEFENSE), GU

    Due5 Dec 2026

  6. Region IX Emergency Medical Membership Access

    COMMUNITY SURVIVOR ASSISTANCE SEC (HOMELAND SECURITY, DEPARTMENT OF), GU

    Due17 Dec 2026

  7. Due31 Jan 2027

  8. USS EMERY S LAND Steam Valves

    MILITARY SEALIFT FLEET SUPPORT CMD (DEPT OF DEFENSE), GU

    Due6 Nov 2027

Find the next one

This one has closed. Get the open bids that fit what you sell by email.

Get similar opportunities by email