J065-- Service GE CT/MRI
At a glance
J065-- Service GE CT/MRI is a federal contract from 252-NETWORK CONTRACT OFFICE 12 (36C252) (VETERANS AFFAIRS, DEPARTMENT OF), in US. Responses are due 2 Dec 2026. It was posted 23 Nov 2026. The solicitation number is 36C25227Q0107. Its NAICS code is 811210. The buyer's notice has the documents and how to respond.
Overview
- Buyer
- 252-NETWORK CONTRACT OFFICE 12 (36C252) (VETERANS AFFAIRS, DEPARTMENT OF)
- Place
- US
- Type
- Federal contract
- Solicitation number
- 36C25227Q0107
- Status
- Open
Key dates
- Posted
- 23 Nov 2026
- Responses due
- 2 Dec 2026
- Time and time zone
- Not stated. Check the buyer's notice.
Summary
The buyer's description, as posted.
Under Statutory Authority 41 U.S.C. 4106(c) the VA Great Lakes Acquisition Center (GLAC) intends to negotiate a sole source contract with GE Precision Healthcare LLC for full-service maintenance and emergency repairs on the imaging equipment and software, (See SOW below). This acquisition is conducted under the authority of 41 U.S.C. 4106(c) order against multiple award schedule as implemented in FAR 16.507-4, only one responsible source and no other supplies or services will satisfy agency requirements. This will be a firm fixed price contract for base plus four option periods. The NAICS Code is 811210. This Notice of Intent is not a request for competitive quotes. No solicitation documents are available and telephone requests will not be honored. However, if a firm believes it can meet the requirements it must furnish information about its products and services, as well as references from other customers who are using these products and service to the Contracting Officer by 9:00AM (local time) 12/02/2026. Supporting evidence must be furnished in sufficient detail to demonstrate the ability to comply with the above requirements. Responses received will be evaluated however; a determination by the Government not to compete the proposed procurement based upon responses to this notice is solely within the discretion of the Government. If no responses are received, the Contracting Officer will proceed with the sole source negotiation with the GE Precision Healthcare LLC. Capability statements shall be submitted by email only as a MS Word or Adobe PDF attachment to Lori. Eastmead @ Lori.Eastmead@va.gov. TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED. STATEMENT OF WORK/SPECIFICATIONS SCOPE: Contractor shall provide labor, travel expenses, parts, material, tools, software and licensing, and equipment necessary to provide full-service Maintenance and Emergency Repairs of the G.E. Equipment and software outlined in Attachment A below. Equipment is located at William S. Middleton, Madison VA, 2500 Overlook Terrace, Madison, WI 53705 VISN 12. Attachment A Room EE# Site#- Sys ID Serial # DG237 (Discovery) CT750-64 47959 608280 CT750 Gantry: 441638CN4 DG500 1.5Tesla MRI 52415 608VAARTIST HM17998 DG513 GE MR MAGNET MAINTENANCE AND CRYOGEN (MSC28Z) 608VAARTISTC DIMPLEX MV PR DIMPLEX WO2-2-5000 CHILLER 20T (SDI020) 76668 608VAARTISTCH W136510-001 DG245B 3Tesla MRI 47960 608VAMR750W UA0436 DG245C GE MR MAGNET MAINTENANCE AND CRYOGEN (MSC28Z) 608VAMR750WC DIMPLEX MV PR DIMPLEX WO2-2-7500 CHILLER 30T (SDI030) 76667 608VAMR750WCH1 W006937-001 *NOTE: Software includes all components of Software that are available for coverage. Coverage shall include all technical aspects and all software and enterprise, and base aspects related to the product. Hardware shall be excluded for coverage relating to Software. CONTRACT PERIOD: Contract shall be a base period (12 months) with renewal options for four (4) additional periods to be exercised at the discretion of the government. CONFORMANCE STANDARDS: Contract service shall ensure that the equipment functions in conformance with the latest published edition of applicable industry standards, including but not limited to the National Electrical Code (NEC), National Fire Protection Association (NFPA-99), Underwriters Laboratories (UL), Occupational Safety and Health Administration (OSHA), VA, Center for Devices and Radiological Health (CDRH), Federal, State, and local codes. Equipment defined herein shall be maintained in accordance with the manufacturer's standards/specifications. Preventive Maintenance inspection/repair procedures shall be in accordance with the manufacturer's specifications and schedule for Preventive Maintenance (PM). The C&A requirements do not apply, and Security Accreditation Package is not required. OPERATIONAL UPTIME REQUIREMENTS: The equipment shall be operable and available for use 95% of the normal operating hours of the equipment as detailed in Paragraph 4, HOURS OF COVERAGE…
Shortened here. The full text is in the buyer's notice.
Requirements
- NAICS code
- 811210
- Product or service code
- J065
Official notice
The buyer's own page for this bid, with its documents and any changes.
Related open bids
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Pursue it in Capveon
Read the documents, check the requirements against your team and draft the response in one place.