Skip to content

Capveon III is here: sell to government in the US, Canada and the UK.Read more

J061--Eaton Powerware System Replacement

241-NETWORK CONTRACT OFFICE 01 (36C241) (VETERANS AFFAIRS, DEPARTMENT OF), New Hampshire. Due 30 Nov 2026.

At a glance

J061--Eaton Powerware System Replacement is a federal contract from 241-NETWORK CONTRACT OFFICE 01 (36C241) (VETERANS AFFAIRS, DEPARTMENT OF), in New Hampshire. Responses are due 30 Nov 2026. It was posted 24 Nov 2026. The solicitation number is 36C24127Q0030. It is set aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14). Its NAICS code is 811310. The buyer's notice has the documents and how to respond.

Overview

Buyer
241-NETWORK CONTRACT OFFICE 01 (36C241) (VETERANS AFFAIRS, DEPARTMENT OF)
Place
New Hampshire
Type
Federal contract
Solicitation number
36C24127Q0030
Status
Open

Key dates

Posted
24 Nov 2026
Responses due
30 Nov 2026
Time and time zone
Not stated. Check the buyer's notice.

Summary

The buyer's description, as posted.

36C24127Q0030 UPS Eaton Powerware System Replacement - RFIs Does the VA require technicians performing quarterly and annual preventive maintenance to be individually factory-certified or authorized by Eaton? Due to the complex nature of the product and criticality - Yes Will documented experience and technical qualifications satisfy the qualification requirement for routine preventive maintenance? See answer to RFI 1 Is direct access to Eaton's proprietary field-service software mandatory for the prime contractor, or may that requirement be fulfilled through an Eaton-authorized service provider supporting specific procedures? Prime Contractor does not require that; That portion can be filled through an Eaton Authorized Technician. Would a contractor be considered technically acceptable if it performs routine maintenance using qualified technicians and subcontracts manufacturer-restricted procedures and startup to Eaton? Yes, minor PM work such as filter changes etc. would be outside the requirement of needing an Eaton Technician. Since Eaton has discontinued the 93E product line, will the VA accept the current Eaton 93PM or another equivalent replacement system meeting the required performance specifications? The VA would accept an Eaton alternative. The goal of the project is to replace existing equipment in-kind with newer model. Does the existing Eaton Powerware 9390 system have an external maintenance bypass (for example, a maintenance bypass panel or a bypass sidecar with maintenance bypass and isolation breakers)? Yes, See photos. Is the replacement expected to include a maintenance bypass sidecar, such as the Eaton 93E 60 kVA bypass sidecar shown in Attachment A, or is it limited to the UPS and Extended Battery Cabinet listed in SOW Section 3.5? The UPS is required to be able to go into maintenance Bypass and maintain power to the computer room during maintenance. What is the kVA rating of the existing unit? The SOW says "Model 80," but the replacement is specified at 60 kVA. Existing UPS is 80KVA. The goal is to replace-in- kind. The 60kVA was utilized as a basis of design. What are the existing input voltage and output voltage? Current system: Eaton Powerware 9390-80 Model 80 AC IN: 208VAC 3W 60Hz 3Phase 240A AC OUT: 208VAC 4W 60Hz 3Phase 222A 78KW 80KVA BYPASS: 208VAC 4W 60Hz 3Phase 222A 80KVA DC: 384-480Vdc 204A Please provide a photo of the existing unit's data plate. See attached photos Please provide photos of the full system (standing back) and of the battery cabinet and batteries. See attached photos Please confirm the battery quantity and model: 40 x Hitachi Chemical Energy Technology 12V 540W, HRC12540WP. Confirmed What is the current battery run time, and what run time is required for the replacement? 60 minutes would it be possible to forward the latest performance specifications/Source Control Drawings for the Powerware System attached Will the VA be paying invoices on a Net-30/45/60 schedule? The VA approves all invoices within 15 days and funds are transferred within 30 days of receipt.

Requirements

Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
NAICS code
811310
Product or service code
J061

Official notice

The buyer's own page for this bid, with its documents and any changes.

Read the buyer's notice

All federal contracts
  1. FCI Berlin FY27 2ND QTR Beef

    FCI BERLIN (JUSTICE, DEPARTMENT OF), NH

    Due30 Nov 2026

  2. FCI Berlin FY27 2ND QTR Kosher

    FCI BERLIN (JUSTICE, DEPARTMENT OF), NH

    Due30 Nov 2026

  3. FCI Berlin FY27 2ND QTR Meats

    FCI BERLIN (JUSTICE, DEPARTMENT OF), NH

    Due30 Nov 2026

  4. FCI Berlin FY27 2ND QTR Subsistence

    FCI BERLIN (JUSTICE, DEPARTMENT OF), NH

    Due30 Nov 2026

  5. FCI Berlin FY27 2ND QTR Bread & Dairy

    FCI BERLIN (JUSTICE, DEPARTMENT OF), NH

    Due30 Nov 2026

  6. J061--Eaton Powerware System Replacement

    241-NETWORK CONTRACT OFFICE 01 (36C241) (VETERANS AFFAIRS, DEPARTMENT OF), NH

    Due30 Nov 2026

  7. FCI Berlin FY27 2ND QTR Meats

    FCI BERLIN (JUSTICE, DEPARTMENT OF), NH

    Due30 Nov 2026

  8. Snow Removal and Landscaping Services at Multiple FAA Facilities in Nashua, NH

    697DCK REGIONAL ACQUISITIONS SVCS (TRANSPORTATION, DEPARTMENT OF), NH

    Due15 Dec 2026

Pursue it in Capveon

Read the documents, check the requirements against your team and draft the response in one place.

Start pursuing thisGet similar opportunities by email