J041--FY27 NRM | 460-26-011 - CON Replace West Entrance Return Air Gan | NCO 4 Construction East (VA-26-00069614)
At a glance
J041--FY27 NRM | 460-26-011 - CON Replace West Entrance Return Air Gan | NCO 4 Construction East (VA-26-00069614) is a federal contract from 244-NETWORK CONTRACT OFFICE 4 (36C244) (VETERANS AFFAIRS, DEPARTMENT OF), in Delaware. Responses are due 21 Dec 2026. It was posted 23 Nov 2026. The solicitation number is 36C24426B0025. It is set aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14). Its NAICS code is 236220. The buyer's notice has the documents and how to respond.
Overview
- Buyer
- 244-NETWORK CONTRACT OFFICE 4 (36C244) (VETERANS AFFAIRS, DEPARTMENT OF)
- Place
- Delaware
- Type
- Federal contract
- Solicitation number
- 36C24426B0025
- Status
- Open
Key dates
- Posted
- 23 Nov 2026
- Responses due
- 21 Dec 2026
- Time and time zone
- Not stated. Check the buyer's notice.
Summary
The buyer's description, as posted.
VA Medical Center Wilmington intends to issue a construction contract. The project consists of: The Contractor shall provide all labor, transportation, materials, equipment, and supervision required for Replace West Entrance Return Air Fan as required at the Wilmington VA Healthcare System, located at 1601 Kirkwood HWY, Wilmington, Delaware 19805. Replace West Entrance Return Air Fan Area is located on the roof of Building 17. Work to take place during normal working hours. Provide correct size crane per lift requirements. Remove existing failed Return Air Fan. Disconnect Electrical power, control signal cabling Install new Return Air Fan ( provided by the VA). COOK Model Number 245QMXD11 900 lbs shipping weigh (see Atch 1) Properly dispose of old return air fan. Perform all necessary commissioning and startup of new equipment. All work to be performed in accordance with manufacturer s recommendations and guidelines. All Federal and State Safety and Environmental guidelines shall be followed. Work to be conducted during normal working hours. Extended hours may be arranged if necessary to fully complete performance of the work. The contractor will need to provide a certified crane operator to remove the old parts and install the new fan motor and housing parts on the roof top. Crane lift plan to be submitted, reviewed and approved by COR prior to commencement of work. Verification that return fan remains integrated into existing BAS system. Currently Johnson Controls speaking BACNET. Work to be scheduled to interfere as little as possible with normal VA operations. Crane lift is to be performed off hours to ensure that NO personnel are below the area of swing during the crane lift evolution. Other Specifics: Prime Contractor to plan all phasing of work in coordination with Hospital staff in order to minimize down-time to areas affected by the project. Construction Waste Management, Specification 01 74 19 is to be included. Prime Contractor to maintain all infection control/ dust prevention measures required. Consolidate all necessary submittals by specification section on an excel spreadsheet. Checklist to be utilized to track/ monitor submittal process. Contractor will submit picture of affected area before, during, and after construction or testing.
Requirements
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- NAICS code
- 236220
- Product or service code
- J041
Official notice
The buyer's own page for this bid, with its documents and any changes.
Related open bids
Due1 Dec 2026
Due2 Dec 2026
Due2 Dec 2026
Due2 Dec 2026
Due2 Dec 2026
Due5 Dec 2026
Due8 Dec 2026
Due9 Dec 2026
Pursue it in Capveon
Read the documents, check the requirements against your team and draft the response in one place.