High-Velocity Water-Cable Safety Barriers and Crash Attenuator Systems
At a glance
High-Velocity Water-Cable Safety Barriers and Crash Attenuator Systems is a federal contract from FLETC GLYNCO PROCUREMENT OFFICE (HOMELAND SECURITY, DEPARTMENT OF), in Georgia. Responses were due 23 Sep 2026. It is closed and no longer taking bids. It was posted 19 Sep 2026. The solicitation number is 70LGLY26QGLB00056. It is set aside: Total Small Business Set-Aside (FAR 19.5). Its NAICS code is 3329. The buyer's notice has the documents and how to respond.
Overview
- Buyer
- FLETC GLYNCO PROCUREMENT OFFICE (HOMELAND SECURITY, DEPARTMENT OF)
- Place
- Georgia
- Type
- Federal contract
- Solicitation number
- 70LGLY26QGLB00056
- Status
- Closed
Key dates
- Posted
- 19 Sep 2026
- Responses due
- 23 Sep 2026
- Time and time zone
- Not stated. Check the buyer's notice.
Summary
The buyer's description, as posted.
9/19/2026 Subject: Amendment 0001, Questions and Answers Amendment 0001 The purpose of this amendment is to provide the Government's responses to question received regarding the delivery time. All other terms and conditions remain unchanged. Question 1: Given this manufacturer's delivery schedule, please confirm whether the Government will maintain the 60-calendar-day delivery requirement or consider revising the delivery schedule to allow full delivery within approximately 100 calendar days. Answer 1: Based on the information provided, the Government will revise the delivery requirement from 60 calendar days after receipt of order (ARO) to 100 calendar days ARO. ******************************************************************************** 1. Description and Required Regulatory Statements (FAR 12.202(b)(1)(i)) This is a combined synopsis/solicitation for commercial products prepared in accordance with the format in Federal Acquisition Regulation (FAR) Part 12 (Acquisition of Commercial Products and Commercial Services), as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; offers/quotes are being requested and a separate written solicitation will not be issued. Solicitation number 70LGLY26QGLB00056 is issued as a Request for Quotation (RFQ) for the procurement and delivery of six hundred and forty-nine (649) portable, water-filled, cable-reinforced longitudinal safety barriers and six (6) compatible, anchorless, water-filled crash attenuator end treatments to support emergency driver training operations on Emergency Response Ranges #7 and #8 at FLETC Glynco, GA. This acquisition is 100% set-aside for Small Business concerns. This solicitation incorporates provisions and clauses by reference with the same force and effect as if they were given in full text. The full text of FAR and Homeland Security Acquisition Regulation (HSAR) provisions and clauses may be accessed electronically at https://www.acquisition.gov. The Defense Priorities and Allocations System (DPAS) assigned rating is Not Applicable. 2. Schedule of Supplies / Services & Quoted Line Items (FAR 12.202(b)(1)(ii)) CLIN 0001 - Water-Filled, Cable-Reinforced Safety Barriers, QTY 649, EA CLIN 0002- Compatible Crash Attenuator End Treatments, Qty 6, EA CLIN 0003-FOB Destination Shipping & Freight, Qty 1, LOT 3. Description of Requirement & Salient Characteristics (FAR 12.202(b)(1)(iii)) A. Background & Operational Scope The Federal Law Enforcement Training Centers (FLETC) requires the direct supply and delivery of high-performance water-filled safety barriers and impact crash cushions to contain, redirect, and safely decelerate errant training vehicles during high-speed emergency response maneuvers on Ranges #7 and #8. This contract is strictly for manufacture, assembly hardware, and delivery; on-site filling, ballasting, and deployment will be accomplished by Government personnel. B. Salient Characteristics for CLIN 0001 (Water-Cable Barriers - Qty: 649) Dimensions: Length: 75" to 76" per section; Height: 43" to 46"; Width: 18" to 22.5". Weights: Empty weight: 160 lbs. to 215 lbs. to allow manual movement prior to filling; Filled ballasted weight: 2,000 lbs. to 2,150 lbs. when ballasted with municipal tap water. Material: Durable, high-density, UV-stabilized polyethylene plastic with molded forklift pass-through pockets and stacking lugs. Internal Cable Reinforcement: Minimum of four (4) integrated, corrosion-resistant internal steel cables running longitudinally through the barrier body, interconnecting section-to-section to establish a continuous high-strength tension line. Connection System: Interlocking multi-knuckle hinge design secured with galvanized steel T-pins and keeper pins, allowing up to 15 degrees of articulation per joint to accommodate track curves. Crash-Test Certification: Independently certified under NCHRP Report 350 and/or AASHTO MASH criteria for Test Level 3 (TL-3)…
Shortened here. The full text is in the buyer's notice.
Requirements
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS code
- 3329
- Product or service code
- 5660
Official notice
The buyer's own page for this bid, with its documents and any changes.
Related open bids
Due27 Nov 2026
Due27 Nov 2026
Due28 Nov 2026
Due28 Nov 2026
Due28 Nov 2026
Due30 Nov 2026
Due30 Nov 2026
Due30 Nov 2026
Find the next one
This one has closed. Get the open bids that fit what you sell by email.