Galveston HVAC Repair/Replacement
At a glance
Galveston HVAC Repair/Replacement is a federal contract from DEPT OF COMMERCE NOAA (COMMERCE, DEPARTMENT OF), in Texas. Responses were due 16 Sep 2026. It is closed and no longer taking bids. It was posted 4 Sep 2026. The solicitation number is 1333MF26Q0110. It is set aside: Total Small Business Set-Aside (FAR 19.5). Its NAICS code is 238220. The buyer's notice has the documents and how to respond.
Overview
- Buyer
- DEPT OF COMMERCE NOAA (COMMERCE, DEPARTMENT OF)
- Place
- Texas
- Type
- Federal contract
- Solicitation number
- 1333MF26Q0110
- Status
- Closed
Key dates
- Posted
- 4 Sep 2026
- Responses due
- 16 Sep 2026
- Time and time zone
- Not stated. Check the buyer's notice.
Summary
The buyer's description, as posted.
COMBINED SYNOPSIS/SOLICITATION - SEE ATTACHMENTS FOR COMPLETE SOLICITATION WITH SF18 The purpose of this requirement is for Services, non-personal, to provide all labor, equipment and materials (unless otherwise provided herein) necessary for non-personal services to furnish all labor, supervision, materials, equipment, permits, tools, transportation, and incidentals necessary to install five (5) new ductless mini-split HVAC systems in the Wet Lab area at the NOAA facility located at 4900 Fort Crockett Boulevard, Galveston, Texas 77551. The systems are to be placed as follows: four (4) to replace failing systems in the Turtle Hospital and the Wet Lab Area, the fifth is a new installation that will go in the Turtle Barn; this unit will have dual internal heads. The installation shall provide reliable temperature control to support laboratory operations while complying with all applicable federal, state, and local codes. (i) This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation. Quotes are being requested and a separate written solicitation will not be issued. Solicitation number 1333MF26Q0110 is issued as a request for quotation (RFQ), for non-personal services to furnish all labor, supervision, materials, equipment, permits, tools, transportation, and incidentals necessary to install five (5) new ductless mini-split HVAC systems in the Wet Lab area at the NOAA facility located at 4900 Fort Crockett Boulevard, Galveston, Texas 77551. The systems are to be placed as follows: four (4) to replace failing systems in the Turtle Hospital and the Wet Lab Area, the fifth is a new installation that will go in the Turtle Barn; this unit will have dual internal heads. The installation shall provide reliable temperature control to support laboratory operations while complying with all applicable federal, state, and local codes. This acquisition is set-aside for small business concerns. The associated NAICS code is 238220. The small business size standard is $19 Million. The Government intends to award a trade-off, single award firm fixed-price purchase order on an all or none with payment terms of Net 30. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. (ii) A list of line-item number(s) and items, quantities, and units of measure (including option(s), if applicable). CLIN 0001 - Non-personal services to furnish all labor, supervision, materials, equipment, permits, tools, transportation, and incidentals necessary to install five (5) new ductless mini-split HVAC systems in the Wet Lab area at the NOAA facility located at 4900 Fort Crockett Boulevard, Galveston, Texas 77551. The systems are to be placed as follows: four (4) to replace failing systems in the Turtle Hospital and the Wet Lab Area, the fifth is a new installation that will go in the Turtle Barn; this unit will have dual internal heads. The installation shall provide reliable temperature control to support laboratory operations while complying with all applicable federal, state, and local codes. CLIN 1001 - Option Year 1 Option year 1 -Non-personal services to provide quarterly preventive maintenance (PM) services for all five (5) installed mini-split HVAC systems per the original statement of work: Preventive maintenance shall include, at a minimum: Four (4) quarterly preventive maintenance visits. Inspection and cleaning of indoor evaporator coils and outdoor condenser coils. Cleaning or replacement of air filters as recommended by the manufacturer. Inspection and cleaning of condensate drain pans and drain lines. Inspection of refrigerant piping, insulation, and fittings for leaks or damage. Verification of refrigerant pressures and operating temperatures. Inspection and tightening of electrical connections. Inspection of disconnect…
Shortened here. The full text is in the buyer's notice.
Requirements
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- NAICS code
- 238220
- Product or service code
- J041
Official notice
The buyer's own page for this bid, with its documents and any changes.
Related open bids
Due27 Nov 2026
Due27 Nov 2026