Skip to content

Capveon III is here: sell to government in the US, Canada and the UK.Read more

Endoscopy Systems

ClosedFDA OFFICE OF ACQ GRANT SVCS (HEALTH AND HUMAN SERVICES, DEPARTMENT OF), Maryland. Was due 16 Sep 2026.

At a glance

Endoscopy Systems is a federal contract from FDA OFFICE OF ACQ GRANT SVCS (HEALTH AND HUMAN SERVICES, DEPARTMENT OF), in Maryland. Responses were due 16 Sep 2026. It is closed and no longer taking bids. It was posted 10 Sep 2026. The solicitation number is 75F40126Q00381. Its NAICS code is 423490. The buyer's notice has the documents and how to respond.

Overview

Buyer
FDA OFFICE OF ACQ GRANT SVCS (HEALTH AND HUMAN SERVICES, DEPARTMENT OF)
Place
Maryland
Type
Federal contract
Solicitation number
75F40126Q00381
Status
Closed

Key dates

Posted
10 Sep 2026
Responses due
16 Sep 2026
Time and time zone
Not stated. Check the buyer's notice.

Summary

The buyer's description, as posted.

Under FDA guidance, this OSEL-DIDSR collaboration requires an endoscope to maximize scientific research capacity throughout the center and agency. An endoscope allows OSEL researchers to develop bench testing methods for evaluating the safety and effectiveness of endoscopy devices. The Government requires an endoscope system (Endoscope) with the following minimum requirements: The Endoscope shall be shipped to the following address: Attention to: TBD 10903 New Hampshire Ave WO62-3133, US FDA Silver Spring, MD 20993- Shipping cost is included in the total purchase price. The Endoscope shall include the video processor, colonoscope, medical display, and cart that are interoperable with each other. Once assembled, these components shall operate as a fully functional endoscopy system that can acquire and display live image. The video processor shall satisfy the following requirements: The video processor shall be an FDA-cleared 510(k) medical device. The database is publicly available at 510(k) Premarket Notification. The light source shall be integrated within the video processor. The light source shall use three (3) or more LEDs to synthesize different spectra. The video processor shall have the white light mode. The video processor shall have two (2) or more narrow-band imaging (NBI) modes that utilize different optical spectra generated by the LED-based light source. The NBI modes shall be FDA-cleared for visualizing biological features such as blood vessels or mucosal surfaces. The video processor shall have two (2) or more digital color enhancement modes that utilize different digital image processing techniques. These color enhancement modes shall be FDA-cleared under the FDA product code "PEA". The video processor shall have the following video output ports and video formats: 12G-SDI (3840x2160x60p) 3G-SDI (1920x1080x60p) HD-SDI (1900x1080x60i) The video processor shall have the capability of saving still images in a standard image file format such as TIFF or JPEG. The video processor shall have the capability of saving video clips in a standard video file format. The colonoscope shall satisfy the following requirements: The colonoscope shall be an FDA-cleared 510(k) colonoscope device. The direction of view shall be forward viewing. The field of view shall be 170 degrees or wider. The depth of field shall cover the range of 5-100 mm or wider. The angulation (up/down/right/left) shall be 180 degrees/180 degrees/160 degrees/160 degrees or larger. The colonoscope shall have a water nozzle. The insertion tube diameter shall be 12.8 mm or smaller. The colonoscope shall have an instrument channel with diameter of 3.7 mm or larger. The medical display shall satisfy the following requirements: The signal input ports shall include: 12G-SDI 3G-SDI Display Port HDMI DVI The pixel count shall be equal to or greater than 3840x2160 pixels (4K). The display size (diagonal) shall be equal to or greater than 32 inches. All components in the system shall be powered by the standard 120 volts, 60 Hertz alternating current power in the U.S. The Endoscope shall include a total system warranty for at least one (1) year, inclusive of any parts, labor, travel, and shipping cost to return the system to the original equipment manufacturer (OEM) standards.The Contractor shall deliver the endoscope within six (6) weeks of contract award. The Contractor shall provide a one (1)-year warranty period following system acceptance.

Requirements

NAICS code
423490
Product or service code
6640

Official notice

The buyer's own page for this bid, with its documents and any changes.

Read the buyer's notice

All federal contracts
  1. JM96 Cutter Body

    NSWC INDIAN HEAD DIVISION (DEPT OF DEFENSE), MD

    Due27 Nov 2026

  2. Due27 Nov 2026

  3. M48 Gas Particulate Filter Sets

    NSWC INDIAN HEAD DIVISION (DEPT OF DEFENSE), MD

    Due27 Nov 2026

  4. Program Analysis and Control (PAAC V) Bridge

    NATIONAL AERONAUTICS AND SPACE ADMINISTRATION, MD

    Due27 Nov 2026

  5. Preclinical Medications Discovery and Abuse Liability Testing for NIDA

    NATIONAL INSTITUTES OF HEALTH OLAO (HEALTH AND HUMAN SERVICES, DEPARTMENT OF), MD

    Due27 Nov 2026

  6. Notice of Intent - Illumina MiSeq i100 series instruments

    NATIONAL INSTITUTES OF HEALTH - CC (HEALTH AND HUMAN SERVICES, DEPARTMENT OF), MD

    Due27 Nov 2026

  7. Due27 Nov 2026

  8. Notice of Intent to Sole Source – Werfen USA LLC – ACL TOP 750 Analyzers kits and reagents

    NATIONAL INSTITUTES OF HEALTH OLAO (HEALTH AND HUMAN SERVICES, DEPARTMENT OF), MD

    Due27 Nov 2026

Find the next one

This one has closed. Get the open bids that fit what you sell by email.

Get similar opportunities by email