Skip to content

Capveon III is here: sell to government in the US, Canada and the UK.Read more

Construction of Chilled Water Plant and Site Utility Upgrades at VA Medical Center in West Haven, CT

ClosedW2SD ENDIST NEW ENGLAND (DEPT OF DEFENSE), Connecticut. Was due 6 Nov 2026.

At a glance

Construction of Chilled Water Plant and Site Utility Upgrades at VA Medical Center in West Haven, CT is a federal contract from W2SD ENDIST NEW ENGLAND (DEPT OF DEFENSE), in Connecticut. Responses were due 6 Nov 2026. It is closed and no longer taking bids. It was posted 6 Oct 2026. The solicitation number is W912WJ26RA008. Its NAICS code is 236220. The buyer's notice has the documents and how to respond.

Overview

Buyer
W2SD ENDIST NEW ENGLAND (DEPT OF DEFENSE)
Place
Connecticut
Type
Federal contract
Solicitation number
W912WJ26RA008
Status
Closed

Key dates

Posted
6 Oct 2026
Responses due
6 Nov 2026
Time and time zone
Not stated. Check the buyer's notice.

Summary

The buyer's description, as posted.

The scope of the chilled water plant replacement consists of the demolition of the existing chilled water plant (building 16a) and construction of a new multi-story chilled water plant to include chillers, cooling towers, pumps, and all associated mechanical and electrical equipment. Due to the close proximity of the existing fuel tank farm adjacent to the existing chilled water plant, a new fuel tank farm will need to be constructed as part of the project, which primarily serves the central boiler plant, requiring close coordination with the medical center and ongoing related projects.The scope of the site utility upgrades consists of the replacement and upgrade of the existing fire protection water main and the domestic water main from Campbell Avenue to Building 15. Site utility upgrades also include providing utility main loops of chilled water supply and return, steam supply, condensate return, domestic water supply, and fire protection water supply which will originate from the new chilled water plant and back-feed to Building 1. The work also includes the installation of redundant electrical feeder from the utility demarcation point to Building 19 and coordination with the local electrical utility provider to provide further electrical redundancy offsite as well. In addition, new water storage tanks will be constructed. This project involves civil/site, mechanical, electrical, plumbing, structural, geotechnical, and architectural disciplines. The project must also comply with the DVAs Physical Security Resiliency Design Requirements (PSRDM). It is expected that the chilled water plant will be constructed to meet USGBC LEED Silver certification. The work is located adjacent to and within an active Medical Center campus which will be operational at all times. Impact to on-going operations must be kept to a minimum and carefully coordinated with the Contracting Officer and VAMC staff. In addition, the work area is constrained due to the active medical center operations which will limit laydown and storage areas during construction.

Requirements

NAICS code
236220
Product or service code
Y1NB

Official notice

The buyer's own page for this bid, with its documents and any changes.

Read the buyer's notice

All federal contracts
  1. Due30 Nov 2026

  2. Due30 Nov 2026

  3. Procurement of Manual Bus Transfer Cables

    SUP OF SHIPBUILDING GROTON (DEPT OF DEFENSE), CT

    Due30 Nov 2026

  4. Periodical Journal Subscriptions

    NAVSUP FLT LOG CTR NORFOLK (DEPT OF DEFENSE), CT

    Due30 Nov 2026

  5. Procurement of Manual Bus Transfer Cables

    SUP OF SHIPBUILDING GROTON (DEPT OF DEFENSE), CT

    Due30 Nov 2026

  6. Due1 Dec 2026

  7. COMMERCIAL NAVIGATION COMPACT INTERCONNECTION BOX

    NAVSUP FLT LOG CTR NORFOLK (DEPT OF DEFENSE), CT

    Due1 Dec 2026

  8. Weapons Shipping Harness Refurbishment Blanket Purchase Agreement

    SUP OF SHIPBUILDING GROTON (DEPT OF DEFENSE), CT

    Due3 Dec 2026

Find the next one

This one has closed. Get the open bids that fit what you sell by email.

Get similar opportunities by email