4320--Condensate Receiver
At a glance
4320--Condensate Receiver is a federal contract from 242-NETWORK CONTRACT OFFICE 02 (36C242) (VETERANS AFFAIRS, DEPARTMENT OF). Responses were due 1 Nov 2026. It is closed and no longer taking bids. It was posted 27 Oct 2026. The solicitation number is 36C24227Q0088. Its NAICS code is 333914. The buyer's notice has the documents and how to respond.
Overview
- Buyer
- 242-NETWORK CONTRACT OFFICE 02 (36C242) (VETERANS AFFAIRS, DEPARTMENT OF)
- Place
- Not stated
- Type
- Federal contract
- Solicitation number
- 36C24227Q0088
- Status
- Closed
Key dates
- Posted
- 27 Oct 2026
- Responses due
- 1 Nov 2026
- Time and time zone
- Not stated. Check the buyer's notice.
Summary
The buyer's description, as posted.
1.0 DISCLAIMER This Request for Information (RFI) is issued in accordance with the RFO FAR 10.001 to determine the availability and technical capabilities of qualified sources. Please respond to the questions in section 3.0. The associated North American Industrial Classification System (NAICS) code for this procurement is 333914, Measuring, Dispensing, and Other Pumping Equipment Manufacturing, with a small business size standard of 750 employees. The RFO FAR Provision found at 52.204-7(b)(1) requires that all offerors obtain a UEI to register in SAM. You may access the SAM website at https://www.sam.gov/portal/public/SAM/. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified by the Small Business Administration at the time of quote submission. This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This RFI is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. 2.0 DESCRIPTION OF ANTICIPATED NEED The Buffalo VA Medical Center is seeking to replace its Domestic Model 52CB45-15 Duplex Condensate Unit (15 psig rated) for integration into the existing piping, supporting facility operations. This procurement is necessary to replace an existing aging condensate receiver with a functionally identical, capacity-matched, pressure-rated unit to ensure full compatibility with current piping, controls, and operating conditions. General Requirements The contractor shall furnish one (1) new Domestic 52CB45-15 Duplex Condensate Unit, factory-assembled and tested; ensure the unit includes all standard manufacturer components; and provide documentation verifying the unit is rated for 15 psig and matches the configuration needed to avoid piping modifications. Technical Requirements The supplied equipment must meet the following: Model Domestic 52CB45-15; duplex pump arrangement; tank construction matching existing inlet/outlet configuration; operating pressure rating of at least 15 psig; electrical compatibility with facility distribution; and pump performance equal to or exceeding existing needs without exceeding system limitations. Delivery Requirements The contractor shall coordinate delivery with facility engineering personnel; ensure equipment arrives fully protected; and provide manufacturer documentation including O&M manuals, warranty information, and pump curves for acceptance. Installation Notes (By Facility or Separate Contract) This procurement covers equipment purchase only. All connection points on the new unit must match existing field piping interfaces to ensure installation without modifications. Contractor shall provide dimensional drawings verifying this requirement prior to shipment. Specs and manufacturer: Receiver Manufacturer Model # Quantity Duplex / Type B pump design Domestic 52CB45-15 1 System shall be 45,000 Sqft EDR capacity with a discharge pressure of 10-15PSIG with a ¾ horsepower motor at 3500RPM. The discharge size shall be 1-1/2 EXCLUSIONS This SOW does not include piping modifications, electrical work, startup or commissioning services, or disposal of the existing condensate receiver. PERIOD OF PERFORMANCE Delivery shall occur within 30 calendar days after receipt of an approved purchase order, unless otherwise coordinated. WARRANTY The manufacturer s standard twenty-year minimum warranty applies, covering defects in materials and workmanship. Contractors must be available and on site for any warranty work within…
Shortened here. The full text is in the buyer's notice.
Requirements
- NAICS code
- 333914
- Product or service code
- 4320
Official notice
The buyer's own page for this bid, with its documents and any changes.
Related open bids
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Due27 Nov 2026
Find the next one
This one has closed. Get the open bids that fit what you sell by email.